Rinnai Leak Detection in Biloxi, MS: Code 79, Condensate or a Real Leak?
Water under a Rinnai tankless heater is not always a failed unit. It can be condensate, a valve seal, a loose fitting or a hot water pipe leaking elsewhere. Need emergency or same-day leak detection? We work across Biloxi and the nearby coast. We are open 24 hours and trace the water with heat, sound, moisture and pressure tests, with no digging.
Makes hot water on demand, with no storage tank. Some units sense water at the bottom and show code 79.
What we do
We tell condensate, a weeping valve and a leaking hot line apart, then mark the spot and give you a written report.
Who repairs
A licensed plumber does the repair or replacement. We do not sell, install or repair Rinnai products.
Short answer
Short answer
Switch off power, shut the gas valve and close the cold water isolation valve. Rinnai's own bulletin links code 79 to leak detection at the bottom of the unit, and it notes that damp air can cause false code 79 alerts. So a code is a reason to look, not proof. We find the true source, and a licensed plumber repairs it.
The basics
Why Is My Rinnai Tankless Water Heater Leaking?
A tankless heater has no storage tank, but it still has parts that can leak. There are isolation valves, an inlet filter, seals and unions, a heat exchanger and a drain for condensate. The unit also ties into your hot and cold lines, so a pipe leak nearby can look like a heater leak.
The key is to sort the water by type. Some of it is normal, such as condensate from a condensing model. Some of it is a weeping part. And some of it is a pipe problem that has nothing to do with the heater.
Gas, power and water share one cabinet, so do not open it yourself. Dry the outside, watch where drops start and leave the rest to a licensed plumber.
Right now
What to Do Right Now When a Rinnai Tankless Leaks
Take these steps in order. They protect you and slow the water.
Cut power and gas
Switch off the unit at the switch or breaker and close its gas valve.
Stop the water
Close the cold isolation valve, or the main valve if you cannot reach it.
Read the display
Write down any code. Take a photo of the label as well.
Dry and watch
Wipe the outside, the valves and the floor. See where new water appears first.
Skip the repair
A tankless unit needs a trained pro. Do not take off covers.
Smell gas? Leave the building and call 911 from a safe place. Do not use switches or a flame. See the gas smell guide. We do not take gas leak reports.
On the display
What Does Rinnai Code 79 Mean, and Is It a Real Leak?
A Rinnai technical bulletin describes code 79 as a leak detection event. The sensor, which it calls the sensing element, sits at the bottom of the unit. When it detects water, the alarm trips and code 79 shows.
The same bulletin calls some of these events "nuisance code 79s." It says that in humid places, condensate can collect at the bottom of the unit and trip the sensor with no true leak. It adds that a modified sensing element can be fitted to stop the false alerts. That matters on the Gulf Coast, where the air is damp most of the year.
Possible 1
A true leak inside
Water from a seal, a fitting or the heat exchanger reaches the sensor. This needs a pro.
Possible 2
Condensate or damp air
Moisture at the bottom trips the sensor with no leak. A plumber can confirm and ask Rinnai about a fix.
Possible 3
Water from outside the unit
A drip from a pipe or the ceiling lands on or near the unit and trips the sensor.
Do not keep clearing the code and moving on. Look for water first, and check your manual's code list for your model. If you are not sure which of the three you have, our water heater leak detection visit sorts it out.
Maybe not a leak
Condensate or Leak: How to Tell Where the Water Comes From
High-efficiency tankless heaters are called condensing. They squeeze so much heat out of the exhaust that water vapor turns to liquid. That liquid is mildly acidic and leaves through a small drain line, often through a neutralizer. Some drip there is part of normal life.
What you see
Likely meaning
Next step
Slow drip from the drain line while it runs
Normal on a condensing model
Leave it, but watch the volume
Overflow at the trap or neutralizer
Blocked line or full neutralizer
A plumber clears and checks it
Water at an isolation valve
Worn seal after servicing
A plumber swaps the seal
Water from the cabinet seam
Possible internal leak
Shut the supply and call a pro
Dry unit, wet floor
Another pipe or an appliance
Leak detection visit
Check before you assume. Only condensing models make condensate. Look at your label or manual to see which type you own.
Common spots
Common Places a Rinnai Tankless Leaks
These are the spots we check, starting with the easy ones.
Isolation valves
The service valves below the unit hold small seals. Flushing and servicing disturb them, so they may weep later.
Inlet filter and unions
A filter housing, an O-ring or a loose union can drip at the cold inlet or hot outlet.
Condensate trap and line
A clog backs water up, and a drain can freeze in a rare hard cold snap.
Relief valve line
A constant drip may mean high pressure or a tired valve, and a plumber checks both.
Heat exchanger
Scale, corrosion or freeze damage can crack it. A plumber decides repair or replacement.
A pipe near the unit
A line in the wall, ceiling or slab can mimic a heater leak.
Early warning
Does a Rinnai Have Built-In Leak Detection?
Some do. That is what code 79 is about. Rinnai also makes an optional leak detection kit for certain indoor non-condensing models. Its instructions describe a drain pan with a float switch. When water gathers in the pan, the float rises, an internal water valve closes to stop the leak, and the display shows code 79, "Water Leak Detected."
The kit is for certain listed models, so a given unit may not accept it.
Rinnai's instructions say it only senses a leak that drips directly over the pan.
A leak elsewhere in your plumbing will not trigger it.
The manual says to turn off the water supply after code 79 and follow its steps.
Installation involves the unit's wiring, so it is a pro's job. Ask your installer.
Call (228) 471-8031. Our emergency leak detection desk answers day and night, and we try to book same-day visits. The cost is quoted first. The contact page works too.
Common causes are a worn isolation valve seal, a loose union or O-ring, the inlet filter housing, a blocked condensate line on a condensing model, the relief valve line and, less often, a cracked heat exchanger. A pipe close by can also drop water near the unit.
What should I do first if my Rinnai leaks?
Power off, gas valve closed, cold isolation valve shut: that is the order. A gas smell means everyone leaves and someone calls 911 from outside. Stay clear of the exhaust and hot pipes. Write down any code, and leave the cabinet closed.
What does Rinnai code 79 mean?
A Rinnai technical bulletin describes code 79 as a leak detection event. The sensing element at the bottom of the unit trips the alarm when it detects water. Turn off the water supply, look for the source, and call a professional. Check your manual for your model.
Can Rinnai code 79 be a false alarm?
Yes. The bulletin calls some of these "nuisance code 79s" and says condensate can collect at the bottom of the unit in humid places and trip the sensor. It also says a modified sensing element can be fitted. Ask a plumber or Rinnai before you assume there is no leak.
Should I keep clearing code 79 and carry on?
No. First look for water around and under the unit, and check the hot and cold lines. If you find none, the alert may be a false trip, but a pro should confirm. Repeated alerts with no cause are a good reason to book a leak check.
Does a Rinnai have built-in leak detection?
Rinnai describes a sensing element at the bottom that sets off code 79. It also lists an optional leak detection kit for certain non-condensing indoor models. The kit senses only a leak that drips over its drain pan. Check which parts your model has.
What does the Rinnai leak detection kit do?
Rinnai's instructions describe a drain pan with a float switch. When water collects, the float closes an internal water valve and the display shows code 79. It only senses water over the pan, so a leak elsewhere will not trigger it. A pro should install it.
Is water from the condensate line normal?
On a condensing model, yes. These units make mildly acidic condensate that drains through a small line, and some dripping is expected. A blocked drain, an overflowing neutralizer, or water from a valve, fitting or cabinet seam is not normal.
Why is water coming from the bottom of my Rinnai?
The bottom holds the isolation valves, the filter and the condensate drain, so many leaks show up there. It can also be water from a pipe above that ran down. Dry the area and watch where the first drop forms. Call us if you cannot tell.
Can the isolation valves on a Rinnai leak?
Yes. Their seals can weep, especially after a flush or service, since the valves get handled. This is a small part, but the unit has gas and power, so have a licensed plumber replace the seal. We can confirm that the valve is the source.
Why is my Rinnai relief valve dripping?
The valve opens to release pressure. Pressure can climb when taps close, especially with a recirculation pump. A constant drip means a plumber should test the valve and your water pressure. Do not cap it, because it protects the system.
Does scale cause leaks in a tankless heater?
Scale builds up inside the heat exchanger over time and can wear it. Scale alone is not a leak, but it can shorten the life of the part. Ask a plumber how often your water calls for flushing, and keep service records.
Can freezing crack a Rinnai in Mississippi?
It can, though hard freezes are rare here. An unheated spot, a condensate line or exposed pipes can freeze on a very cold night. Insulate what you can, and follow the maker's cold-weather advice in your manual.
Water is near my Rinnai, but the unit looks dry. Where is it from?
It may come from a pipe in the wall or ceiling, an air-conditioner drain, a washer hose or a slab line. We trace the water to its true source. Our slab leak detection page covers lines under the floor.
My Rinnai keeps turning on when no tap is open. Is that a leak?
It can be, because a hidden hot-line leak can create flow that starts the unit. A recirculation setup can also start it on purpose. We test the hot lines and read the meter to tell which. See pipe leak detection.
Can I keep using my Rinnai if it leaks a little?
It is better not to. A small leak can soak a wall or floor, and a leak at a fitting or the heat exchanger can get worse. Shut the water to the unit and call a plumber. Call us if you are unsure of the source.
How do I check my Rinnai warranty?
Terms depend on series, install and use, so we cannot give a number. Read the papers that came with the unit, check Rinnai's own site for your model, and ask your installer how the unit was set up. Keep the model, serial number and install date together.
Do you sell, install or repair Rinnai water heaters?
No. We are independent and not an authorized dealer for Rinnai. We find leaks and write them up. A licensed plumber does any repair or replacement. Brand names belong to their owners.
Can your report help with a warranty or insurance claim?
The report shows where the leak is and which tests found it. Pass it to your plumber, Rinnai or your insurer, with the model, serial number, any code and the install date. Coverage is up to them. We have no say in a claim.
Do you offer tankless leak detection near me in Lyman or Wiggins?
Yes. We cover Biloxi and 20 nearby Gulf Coast towns, including Lyman and Wiggins. Call (228) 471-8031 at any hour. We say whether we can come, and what it costs, before we do.
Sources, Review and Our Limits
By Leak Detection Biloxi team
Reviewed November 2026
Checked against Rinnai's technical bulletin and leak kit instructions and federal gas safety guidance
We find and document leaks. A licensed plumber makes repairs. We are not Rinnai, a gas utility, an insurance adjuster or a water utility. Product notes come from two Rinnai documents and may have changed. Use your own manual and warranty, and verify any plumber's license first.
Keep exploring
More Help With Rinnai and Hidden Leaks
A product can warn you or leak itself. These pages show how we find the real source.
Code 79 or Water Under Your Rinnai? Call Us.
Call now for same-day and 24-hour leak detection. The price comes first.